Skip to content

PVI Tags (Photovoltaic Inverter)

Namespace prefix: 0x02

PVI tags use a data request pattern: send PVI_REQ_DATA as a container with PVI_INDEX and the desired sub-tags.

AC Side

TagHexTypeDescription
PVI_AC_POWER0x028AC001Float32AC power per phase in watts
PVI_AC_VOLTAGE0x028AC002Float32AC voltage per phase in volts
PVI_AC_CURRENT0x028AC003Float32AC current per phase in amps
PVI_AC_FREQUENCY0x028AC00AFloat32Grid frequency in Hz
PVI_AC_ENERGY_ALL0x028AC006Float32Total AC energy in Wh
PVI_AC_ENERGY_DAY0x028AC008Float32Today's AC energy in Wh

DC Side

TagHexTypeDescription
PVI_DC_POWER0x028DC001Float32DC power per string in watts
PVI_DC_VOLTAGE0x028DC002Float32DC voltage per string in volts
PVI_DC_CURRENT0x028DC003Float32DC current per string in amps

Status

TagHexTypeDescription
PVI_REQ_ON_GRID0x02000001NoneRequest grid connection status
PVI_ON_GRID0x02800001BoolTrue if connected to grid
PVI_REQ_STATE0x02000002NoneRequest inverter state
PVI_STATE0x02800002UInt32Inverter state flags

E3DC S10 Pro RSCP Client Library